Skip to content
Aquatopia Groundwater research

Expertise Aquatopia

Water analyses

For obtain authorization to operate a high industrial drilling the regulatory and technical file must validate two Health compliance (no pollution) and the sustainability of facilities (no risks) biocorrosion).

Analysis microbiological (or bacteriological)

The approved laboratory shall certify water conformity according to three categories of pollutants.

The presence of these bacteria evidence of direct contamination by infiltration water or agricultural manure.

  • Escherichia coli and Enterococci: direct control of fecal contamination human or animal.

  • Coliformes Total: indicators of the overall biological quality of the well.

  • Bacteria sulphito-reducing agents (spores): control of faecal pollution older or intermittent.

Pollutants agricultural chemicals

  • Nitrates (Technical formula 𝑁𝑂3) Nitrites (Technical formula 𝑁𝑂2).

  • Screening complete pesticides and herbicides.

Pollutants Industrial and Emerging

  • Hydrocarbon chlorinated solvents.

  • Compounds perfluorinated (PFAS / "Forever Chemicals") : Molecules particularly monitored in industrial settings.

The Technical Diagnosis (Bio-corrosion risks)

Analysis technology bacteria is the most critical point for survival of equipment. It is essential to ask laboratory a specific count to anticipate two threats major.

  • The Ferrobacteria (iron batteries): They oxidize the dissolved iron in water. They create a jelly very sticky redhead (biofilm) that covers the interior of the drive, colmate pump suction and distort measurements Your electromagnetic flow meter.

  • The Sulfato-Reducing Bacteria (BSR): These bacteria develop under biofilm in anaerobic environment (without oxygen). They secrete hydrogen sulphide (H2S) which chemically attacks steel (even stainless steel). That's the cause. n°1 of rapid perforation of steel casings by biocorrosion. 

Analysis physico-chemical and microbiological water is the first mandatory step before connection of a industrial drilling 100 m3/h.

She fulfils three objectives:

- Validation of Regulatory Compliance (Water Act),

- Determination of a possible treatment chain (softener, deferrizer, filtration) and

- Pump protection and your steel pipes against premature wear and tear. 

For you must mandate a laboratory approved by the Department to carry out a sterile sampling at the end of development phase by Air-Lift. 

Cost scale an approved laboratory analysis

  • Pack Standard Drilling (Basic Physicochemistry + Bacteriology): 150 € to 300 € HT

    • Sufficient for a first diagnosis of potability or simple watering. 

  • Pack Industrial / Heavy Process (Complete Physicochemistry, Metals Major minerals): 450 € to 750 € HT

    • Essential for the project. Allows hydraulic engineers to validate the water compatibility with plant process and alloys pump. 

  • Option Multi-Residue Research (Pesticides, PFAS, Hydrocarbons): 300 € to 600 € HT by scope the list of molecules sought. 

Protocol of compulsory levy

For avoid distorting results by introducing bacteria of the sample should be taken according to the strict rules: 

  1. Disinfection the sampling point: Flaming the surface purging valve with the torch or lighter, then disinfect it with alcohol at 70°. 

  2. Purge of the line: Let water flow at high flow for at least 10-15 minutes directly from the pump to remove water Piping stagnant. 

  3. Flaaching sterile: Use only the sterile vial supplied by the laboratory (often containing sodium thiosulfate). Never rinse bottle before filling it. Fill it full and close it immediately. 

  4. Chain cold: The sample shall be placed in a cooler between 2°C and 6°C and brought to the laboratory within 24 hours after sampling. 

If laboratory analysis reveals the presence of microorganisms undesirable, here are the industrial protocols to apply for eliminate contamination. 

The Treatment of Curative Shock (well disinfection)

If the laboratory detects ferrobacteria, bacteria sulfato-reducing agents (BSR) or coliforms, disinfect massively drilling (naked hole, steel casing and pump) before industrial commissioning. 

  • The chemical: Hypochlorite Sodium (48° industrial bleach). It is the most powerful, cheapest and easiest biocide to use. neutralize. 

  • The Impact measurement: A concentration of 100 to 200 mg/L of active chlorine throughout the water volume of the drilling.

    • Volume estimated water in your well: For a hole of 400 mm by 50 meters depth, the volume of stationary water is approximately 6.3 Technical formula (6 300 litres).

    • Quantity To be injected: He must pour about 5 to 7 litres of industrial bleach concentrated directly from the surface in the tubing. 

  • The action procedure:

Pour the product to the top of well.

Start pump, closed surface valve for 15 minutes to make circulation of chlorinated water throughout the discharge column and Well distribute the disinfectant.

Leave act for 12 to 24 hours without pumping. It's time for chlorine to cross the bacterial biofilm and destroy the roots of ferrobacteria embedded in the rock.

The rinse: Open the valve and pump at high flow to reject highly chlorinated water away from the plant, to a basin of decantation or neutralization. Strictly prohibited from sending this water in the network or in a natural watercourse without having it neutralized with sodium thiosulfate as it would destroy the environment. Pump until chlorine smell disappears Totally. 

The Preventive treatment Ongoing

In an active underground river, shock treatment is not enough in the long term, as the direct current will bring back new bacteria. If the risk of biocorrosion is permanent, Two surface treatment solutions should be preferred: 

  • Option A: Continuous injection of Chlorus (Dosing pump)

    • One small dosing pump enslaved to the flowmeter injects chlorine liquid or chlorine dioxide in the pipe. We maintain a very low residual chlorine from 0.2 to 0.5 mg/L.

    • Very economic, protects all the pipes of the plant against the development of biofilm. 

  • Option B: Ultra Violet Sterilizer

    • Water through a stainless steel chamber equipped with lamps to quartz that emit high intensity UV-C rays. These rays instantly destroy the DNA of 99.9% of bacteria (coliforms, ferrobacteria) without changing taste or taste chemical composition of water.

    • For 100 Technical formula /h, an industrial UV cabinet must be installed, usually equipped with 3 to 6 high power amalgam lamps.

    • Count between €4,000 and 7 500 € tax excl. to purchase, plus replacement of lamps every 10,000 hours (about once a year). 

💡 Recommendation for electrician

If you install a UV-C system or a chlorine dosing pump, it must connect the sterilizer malfunction alarm directly on a logical security input from your cabinet Dimmer. If the treatment system fails, the pump will stop automatically, thus avoiding sending water contaminated in the water system. 

The Key parameters to monitor (pump & steel)

Water an underground river in limestone presents risks equipment specific chemicals: 

  • The pH and Langelier Index (IL) indicate if the water is aggressive (corrosive for your steel tubes) or (risk of rapid shutdown of pump turbines). 

  • The Total Hardness (Hydrometric Title): measures calcium and magnesium concentration. Very hard water requires rigorous monitoring to avoid tartar deposits on the engine, which would alter its cooling. 

  • The Iron and Manganese: In pressurized confined media, these metals may be dissolved. In contact with surface air, they oxidize and create sludge adhesives capable of blocking non-return valves and to crack the electrodes of the electromagnetic flow meter. 

  • The Chlorides and Sulfates: high rates increase water conductivity and accelerate galvanic corrosion of carbon steel. If chlorides exceeding 200 mg/L. A 316L stainless steel tubing is required. 

  • The Suspension materials (MES) / Turbidity: Measure the presence of micro-particles of rock removed by the river current. It is this parameter that validates if your Pump turbines will undergo significant abrasive erosion. 

Analysis water chemical

Analysis chemical water from an industrial drilling completes the analysis to ensure regulatory compliance and protect equipment (pump, flow meters).

Here the essential chemical parameters to ask the laboratory Approved: 

The Ionic Major Balance (Equilibrium and Entarrage)

  • The pH and temperature condition all chemical reactions and the effectiveness of future treatments (such as chlorination).

  • The Electrical conductivity translated overall mineralization of water (quantity of dissolved salts).

  • The Title Hydrometric measurement Calcium ions. Water too hard tarnishes sensors; Water too soft corrodes metals.

  • The Title Complete Alcalimetric (TAC) measurement carbonates and bicarbonates, which act as a buffer for stabilize the pH. 

The Biocorrosion indicators

These chemical elements serve as "fuel" to bacteria technologies that we have identified. 

  • The Total iron (𝑭𝒆) and Manganese (𝑴𝒏) : If the iron dissolved is high ( >0 , 2 mg/L), it directly feeds the Ferrobacteria, accelerating the creation of the gelatinous biofilm that obstructs the pipes. 

  • The Sulfates constitute exclusive food of Sulfato-Reducing bacteria. In anaerobic medium under biofilm, BSRs transform these sulphates in hydrogen sulphide, responsible for perforation of tubing Steel. 

  • Oxygen Dissolved and the Potential Redox let us know if your drilling is in oxidizing medium (iron-favourable) or reducing (sulphur-favourable) 

The agricultural and industrial anthropogenic pollutants)

These Exogenous molecules must be strictly screened for obtaining permission to operate. 

Category

Parameters Keys to analyse

Risks major

Pollution Agricultural



Nitrates (𝑵𝑶𝟑) & Nitrites (𝑵𝑶𝟐)
Screening Complete Pesticides / Herbicides


Non-compliance strict regulation,
Fast infiltration via network Karstic.

Pollution Industrial

Hydrocarbon Total
Chlorinated solvents

Degradation joints of the pump,
Groundwater pollution.

Pollutants Emerging

Compounds Perfluorinated
(Forever Chemicals)

Monitoring priority imposed